The S-82G1B Series is a protection IC for lithium-ion / lithium polymer rechargeable batteries, which includes high-accuracy voltage detection circuits and delay circuits. It is suitable for protecting 1-cell lithium-ion / lithium polymer rechargeable battery packs from overcharge, overdischarge, and overcurrent.
Using the S-82G1B Series makes it possible to configure a protection circuit which separates the charge and discharge current paths.
Independent charge current path suppresses heat generation during charging.
Features
- High-accuracy voltage detection circuit
- Overcharge detection voltage: 3.500 V to 4.600 V (5 mV step) Accuracy ±15 mV
- Overcharge release voltage: 3.100 V to 4.600 V*1 Accuracy ±50 mV
- Overdischarge detection voltage: 2.000 V to 3.000 V (10 mV step) Accuracy ±50 mV
- Overdischarge release voltage: 2.000 V to 3.400 V*2 Accuracy ±75 mV
- Discharge overcurrent detection voltage 1: 0.003 V to 0.100 V (0.5 mV step) Accuracy ±1.5 mV
- Discharge overcurrent detection voltage 2: 0.010 V to 0.100 V (1 mV step) Accuracy ±3 mV
- Load short-circuiting detection voltage: 0.020 V to 0.100 V (1 mV step) Accuracy ±5 mV
- Charge overcurrent detection voltage: −0.100 V to −0.010 V (1 mV step) Accuracy ±3 mV
- Detection delay times are generated only by an internal circuit (external capacitors are unnecessary).
- Discharge overcurrent control function
- Load short-circuiting detection 2 function is selectable: Available, unavailable
- Release condition of discharge overcurrent status: Load disconnection
- Release voltage of discharge overcurrent status: VRIOV = VDD × 0.8
- 0 V battery charge function is selectable
- Available, unavailable
- Power-down function is selectable
- Available, unavailable
- High-withstand voltage
- VMC pin, VMD pin and CO pin: Absolute maximum rating 28 V
- Wide operation temperature range
- Ta = −40°C to +85°C
- Low current consumption
- During operation: 2.0 μA typ., 4.0 μA max. (Ta = +25°C)
- During power-down: 50 nA max. (Ta = +25°C)
- During overdischarge: 0.5 μA max. (Ta = +25°C)
- Lead-free (Sn 100%), halogen-free
*1. Overcharge release voltage = Overcharge detection voltage − Overcharge hysteresis voltage
(Overcharge hysteresis voltage can be selected as 0 V or from a range of 0.1 V to 0.4 V in 50 mV step.)
*2. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage can be selected as 0 V or from a range of 0.1 V to 0.7 V in 100 mV step.)
Applications
- Lithium-ion rechargeable battery pack
- Lithium polymer rechargeable battery pack